Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 55(16): 4285-92, 2016 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27411177

RESUMO

The use of a grazing incidence optic to selectively reflect K-shell fluorescence emission and isotope-specific lines from special nuclear materials is a highly desirable nondestructive analysis method for use in reprocessing fuel environments. Preliminary measurements have been performed, and a simulation suite has been developed to give insight into the design of the x ray optics system as a function of the source emission, multilayer coating characteristics, and general experimental configurations. The experimental results are compared to the predictions from our simulation toolkit to illustrate the ray-tracing capability and explore the effect of modified optics in future measurement campaigns.

2.
Rev Sci Instrum ; 86(1): 013110, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25638075

RESUMO

A multilayer-based optic was tested for use as an X-ray diagnostic on a laser-plasma experiment. The multilayer optic was employed to selectively pass X-rays between 55 and 100 keV. An order of magnitude improvement in signal-to-noise ratio is achieved compared to a transmission crystal spectrometer. A multilayer response model, taking into account the source size and spectral content, is constructed and the outlook for application above 500 keV is briefly discussed. LLNL-JRNL-664311.

3.
Opt Express ; 22(18): 21214-26, 2014 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-25321502

RESUMO

This paper reports novel measurements of x-ray optical radiation on an absolute scale from the intense and ultra-short radiation generated in the soft x-ray regime of a free electron laser. We give a brief description of the detection principle for radiation measurements which was specifically adapted for this photon energy range. We present data characterizing the soft x-ray instrument at the Linac Coherent Light Source (LCLS) with respect to the radiant power output and transmission by using an absolute detector temporarily placed at the downstream end of the instrument. This provides an estimation of the reflectivity of all x-ray optical elements in the beamline and provides the absolute photon number per bandwidth per pulse. This parameter is important for many experiments that need to understand the trade-offs between high energy resolution and high flux, such as experiments focused on studying materials via resonant processes. Furthermore, the results are compared with the LCLS diagnostic gas detectors to test the limits of linearity, and observations are reported on radiation contamination from spontaneous undulator radiation and higher harmonic content.

4.
Rev Sci Instrum ; 83(10): 10E525, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23127032

RESUMO

Hohlraums are employed at the national ignition facility to convert laser energy into a thermal x-radiation drive, which implodes a fusion capsule, thus compressing the fuel. The x-radiation drive is measured with a low spectral resolution, time-resolved x-ray spectrometer, which views the region around the hohlraum's laser entrance hole. This measurement has no spatial resolution. To convert this to the drive inside the hohlraum, the size of the hohlraum's opening ("clear aperture") and fraction of the measured x-radiation, which comes from this opening, must be known. The size of the clear aperture is measured with the time integrated static x-ray imager (SXI). A soft x-ray imaging channel has been added to the SXI to measure the fraction of x-radiation emitted from inside the clear aperture. A multilayer mirror plus filter selects an x-ray band centered at 870 eV, near the peak of the x-ray spectrum of a 300 eV blackbody. Results from this channel and corrections to the x-radiation drive are discussed.

5.
Rev Sci Instrum ; 83(4): 043107, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22559515

RESUMO

The soft x-ray materials science instrument is the second operational beamline at the linac coherent light source x-ray free electron laser. The instrument operates with a photon energy range of 480-2000 eV and features a grating monochromator as well as bendable refocusing mirrors. A broad range of experimental stations may be installed to study diverse scientific topics such as: ultrafast chemistry, surface science, highly correlated electron systems, matter under extreme conditions, and laboratory astrophysics. Preliminary commissioning results are presented including the first soft x-ray single-shot energy spectrum from a free electron laser.

6.
Opt Express ; 20(10): 11396-406, 2012 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-22565760

RESUMO

The recent development of x-ray free electron lasers providing coherent, femtosecond-long pulses of high brilliance and variable energy opens new areas of scientific research in a variety of disciplines such as physics, chemistry, and biology. Pump-probe experimental techniques which observe the temporal evolution of systems after optical or x-ray pulse excitation are one of the main experimental schemes currently in use for ultrafast studies. The key challenge in these experiments is to reliably achieve temporal and spatial overlap of the x-ray and optical pulses. Here we present measurements of the x-ray pulse induced transient change of optical reflectivity from a variety of materials covering the soft x-ray photon energy range from 500eV to 2000eV and outline the use of this technique to establish and characterize temporal synchronization of the optical-laser and FEL x-ray pulses.


Assuntos
Óptica e Fotônica/métodos , Eletroquímica/métodos , Eletrônica , Elétrons , Desenho de Equipamento , Lasers , Fótons , Semicondutores , Fatores de Tempo , Raios X
7.
Phys Rev Lett ; 107(14): 144801, 2011 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-22107200

RESUMO

Measurements of the spatial and temporal coherence of single, femtosecond x-ray pulses generated by the first hard x-ray free-electron laser, the Linac Coherent Light Source, are presented. Single-shot measurements were performed at 780 eV x-ray photon energy using apertures containing double pinholes in "diffract-and-destroy" mode. We determined a coherence length of 17 µm in the vertical direction, which is approximately the size of the focused Linac Coherent Light Source beam in the same direction. The analysis of the diffraction patterns produced by the pinholes with the largest separation yields an estimate of the temporal coherence time of 0.55 fs. We find that the total degree of transverse coherence is 56% and that the x-ray pulses are adequately described by two transverse coherent modes in each direction. This leads us to the conclusion that 78% of the total power is contained in the dominant mode.

8.
J Environ Sci Health B ; 44(2): 106-12, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19130368

RESUMO

The aim of this paper is to examine the statistical relevance of bird species on the endpoints of avian long-term toxicity studies (eggs laid, eggs set, eggs hatching, embryo survivor, 14-day old survivors and eggshell thickness). Data from 561 animals of three different species (Colinus virginianus, Anas platyrynchos and Coturnix coturnix japonica) tested with five different pesticides were analyzed in this study. The substances considered were: Thiamethoxam (EZ-3-(2-chloro-1,3-thiazol-5-ylmethyl)-5-methyl-1,3,5-oxadiazinan-4-ylidene(nitro)amine), Thiacloprid ((Z)-3-(6-chloro-3-pyridylmethyl)-1,3-thiazolidin-2-ylidenecyanamide), Acetamiprid ((E)-N(1)-[(6-chloro-3-pyridyl)methyl]-N(2)-cyano-N(1)-methylacetamidine), Phosmet (O,O-dimethyl S-phthalimidomethyl phosphorodithioate) and Dicofol (2,2,2-trichloro-1,1-bis(4-chlorophenyl)ethanol). Several general lineal mixed models were conducted to evaluate the factors affecting variables used in long-term reproductive toxicity tests. Test significance was p < 0.01 in all models tested. Model R(2) value was high (0.80) for all variables except for eggs laid (R(2) = 0.42) for the three species studied. Tukey studentized range test showed significant differences among species and pesticides. For pre-hatching period the differences were significant for eggs laid and eggs set among species. C. japonica showed statistical differences for egg hatching. With respect to embryo survivor and 14 days old survival, significant different were found for C.virginianus and A. platyrynchos, respectively. These results indicate that the selected species have an influence in the endpoints to be used for risk assessment.


Assuntos
Aves/fisiologia , Ecotoxicologia/métodos , Determinação de Ponto Final , Praguicidas/toxicidade , Plantas/efeitos dos fármacos , Reprodução/efeitos dos fármacos , Reprodução/fisiologia , Animais , Aves/embriologia , Embrião não Mamífero/efeitos dos fármacos , Embrião não Mamífero/fisiologia , Óvulo/efeitos dos fármacos , Óvulo/crescimento & desenvolvimento , Óvulo/metabolismo , Medição de Risco , Especificidade da Espécie , Taxa de Sobrevida , Fatores de Tempo , Testes de Toxicidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...